1. safety instructions

- Please read these instructions for use carefully, keep them for future reference, make them available to other users and follow these instructions.

- The target group for this device is the specialist in the respective field: orthopaedic (shoe) technicians, engineers, biomechanics, ergonomists, etc.
The system is not intended for end users.

  • In principle, the specialist should endeavour to expand and develop their specialist knowledge of the biomechanical relationships involved in walking and running, as the device only provides the basics and the specialist must personally decide on the measures to be taken.
  • In the event of occurring or suspected malfunctions, the user should contact the manufacturer at an early stage, especially in the orthopaedic fields of application.
  • This device is a sensitive electronic measuring device.
  • Please handle it with care and do not walk on the appliance with shoes.
  • Do not expose the measuring device to direct sunlight.
  • The device should be in the room in which the measurement is being carried out for at least 30 minutes.
  • The device is not waterproof. For this reason, direct contact with water or other liquids must be avoided. However, if liquid should penetrate the device, further use must be avoided. In this case, please contact the manufacturer.
  • The appliance is only intended for the purpose specified in these instructions for use. Any misuse will invalidate the warranty.
  • Repairs may only be carried out by persons authorised by the manufacturer. Otherwise the warranty will be invalidated.
  • The measuring surface of the device must be cleaned with a soft cloth moistened with disinfectant before or after each use.
  • It must be possible to walk or run in front of and behind the device without tripping.

Laser safety instructions

  • With class 2 laser systems, the accessible laser radiation is harmless to the skin. Short-term irradiation of the eyes is also harmless due to the low power. The eye is protected by the natural eyelid protection reflex during prolonged intensive irradiation.
  • The device uses a laser of laser class 2.
  • To avoid irritation of the eyes during operation, you should not directly into the laser source.
  • Diffuse reflections from the laser are absolutely harmless.

Using the power supply unit

  • Only use the original power supply unit for this device (12 V, 3.0 A). The use of an unauthorised power supply unit can damage the device or be dangerous for this device.
  • Do not place any objects on the mains cable. Also ensure that people do not step on the power cable or get caught in it.
  • Do not use the mains adapter if the device or the mains cable is damaged. Switch off the device and unplug the power adapter from the socket immediately.
  • Never insert or remove the mains cable from the socket with wet hands.
  • Disconnect the appliance from the socket before cleaning it. Do not use any liquid cleaners or sprays. Use a damp cloth for cleaning.
  • Connect the mains adapter before connecting the mains cable to the mains socket.

Unplug the mains cable from the socket before removing the mains adapter from the appliance.