In the following, the measurement is divided into "Scanning of feet" and "Scanning of footfall foams".

 

The device is intended for scanning the plantar foot shape or footstep foams. For this purpose, the device is placed on a firm and non-slip surface or installed in a platform. Either the customer's foot without footwear or a foot foam is placed on the measuring surface (2) of the device. A traversing unit equipped with a camera and laser scans the entire sole of the foot or the tread foam at a speed of 2-4 seconds per scan. A digital photo of the foot is also generated. The data obtained forms the basis for creating a grid model with millimetre-precise measurements of the plantar foot shape and the arch of the foot.

The camera and laser unit are controlled and the measurement data is transferred to the PC via a USB connection. The measured values are displayed on the PC in the GP LaserScan software module and can be analysed there.

 

 

WARNING

 It must be possible to walk or run in front of and behind the device without tripping.

 

 

Please first check that the appliance is complete and undamaged. If in doubt, do not use the appliance and contact the manufacturer.

The scope of delivery of the GP Laser Scan 3D Flat 2 includes

 

  • 1 GP LaserScan 3D Flat 2 (laser scanner for plantar measurement of feet / step foams)
  • 1 power supply unit (12 V, 3.0 A )
  • 1 USB 2.0 connection cable (approx. 3.0 metres)
  • 1 foot switch with connection cable (approx. 2.4 metres)
  • 1 DVD or 1 USB stick (with drivers and tools)
  • 1 instruction manual
  • 2 side footrests

 

The packaging is reusable or can be returned to the raw material cycle. Please dispose of packaging material that is no longer required properly. If you notice any transport damage during unpacking, please contact the manufacturer immediately.

 

WARNING

Make sure that the packaging film does not get into the hands of children.

There is a risk of suffocation!

 

Safety instructions

 

  • Please read these instructions for use carefully, keep them for future reference, make them available to other users and follow these instructions.
  • The target group for this device is the specialist in the respective field: orthopaedic (shoe) technician, engineer, biomechanist, ergonomist, etc.The system is not intended for end users.
  • In principle, the specialist should endeavour to expand and develop his or her specialist knowledge of the biomechanical relationships involved in walking, sitting and running, as the device only provides the basics and the specialist must decide personally on the measures to be taken.
  • In the event of occurring or suspected malfunctions, the user should contact the manufacturer at an early stage, especially in the orthopaedic fields of application.
  • This device is a sensitive electronic measuring device.
  • Do not exceed the maximum load of 140 kg on the device. Then carry out the measurement partially loaded (in a sitting position).
  • Please handle it with care and do not walk on the appliance with shoes.
  • Do not expose the measuring device to direct sunlight.
  • The device should be in the room in which the measurement is being carried out for at least 30 minutes.
  • The device is not waterproof. For this reason, direct contact with water or other liquids must be avoided. However, if liquid should penetrate the device, further use must be avoided. In this case, please contact the manufacturer.
  • The appliance is only intended for the purpose specified in these instructions for use. Any misuse will invalidate the warranty.
  • Repairs may only be carried out by persons authorised by the manufacturer. Otherwise the warranty will be invalidated.
  • The measuring surface of the device must be cleaned with a soft cloth moistened with disinfectant before or after each use.
  • It must be possible to walk or run in front of and behind the device without tripping.

 

Laser safety instructions

 

  • With class 2 laser systems, the accessible laser radiation is harmless to the skin. Short-term irradiation of the eyes is also harmless due to the low power. The eye is protected by the natural eyelid protection reflex during prolonged intensive irradiation.
  • The device uses a laser of laser class 2.
  • To avoid irritation of the eyes during operation, you should not directly into the laser source.
  • Diffuse reflections from the laser are absolutely harmless.

 

Using the power supply unit

  • Only use the original power supply unit for this device (12 V, 3.0 A). The use of an unauthorised power supply unit can damage the device or be dangerous for this device.
  • Do not place any objects on the mains cable. Also ensure that people do not step on the power cable or get caught in it.
  • Do not use the mains adapter if the device or the mains cable is damaged. Switch off the device and unplug the power adapter from the socket immediately.
  • Never insert or remove the mains cable from the socket with wet hands.
  • Disconnect the appliance from the socket before cleaning it. Do not use any liquid cleaners or sprays. Use a damp cloth for cleaning.
  • Connect the mains adapter before connecting the mains cable to the mains socket.
  • Unplug the mains cable from the socket before removing the mains adapter from the appliance.

 

 