Operating manual

GT George Max

GeBioM mbH
Wilhelm-Schickard-Straße 12
Germany - 48149 Münster
Phone +49 251 98724 - 0
Fax +49 251 98724 - 22
E-mail info@gebiom.de
www.gebiom.de

Please contact the manufacturer in the event of a warranty claim. If you need to send in the device, please state the defect and enclose a copy of the invoice.

 

The following warranty conditions apply:

 

  1. GeBioM mbH products are guaranteed for one year from the date of purchase. In the event of a warranty claim, the date of sale must be proven by the purchase receipt or invoice.
  2. Defects due to material or manufacturing faults will be rectified free of charge within the warranty period.
  3. Warranty service does not extend the warranty period, neither for the appliance nor for replaced components.
  4. Excluded from the guarantee are

 

  1. all damage caused by improper handling, e.g. failure to observe the instructions for use.
  2. Damage caused by repairs or tampering by the buyer or unauthorised third parties.
  3. Transport damage that has occurred on the way from the manufacturer to the consumer or during dispatch to the service centre.
  4. Accessories that are subject to normal wear and tear, such as batteries, sensors, etc.

 

  1. Liability for direct or indirect consequential damage caused by the device is excluded even if the damage to the device is recognised as a warranty case.

 

 

 

GeBioM mbH

Wilhelm-Schickard-Str. 12

48149 Münster (Germany)

Phone: +49 (0)251 / 987240

Fax: +49 (0)251 / 9872422

eMail: info@gebiom.com

Internet: www.gebiom.com

Name and model: GT George

Data transfer: USB 2.0 / USB 3.0

Laser class: 2

Connection: 1 x power, normal speed: 1 x USB, high speed: 2x USB plus software dongle

Dimension: approx. 475 mm x 255 mm x 216 mm

Weight: approx. 6.6 kg

Load capacity of the measuring surface: max. 130 kg static

Measuring error: +/- 1mm

Operating conditions: +5°C to +35°C, <80 % max. rel. humidity humidity

Power supply unit: 12 V, 3.0 A

 

In the course of continuous product improvements, we reserve the right to We reserve the right to make technical and design changes.

  • The target group for this device is the specialist in the relevant field: orthopaedic (shoe) technician, engineer, biomechanist, ergonomist, etc.
  • The system is therefore not intended for end users.
  • In principle, the specialist should endeavour to expand and develop his or her specialist knowledge of the biomechanical relationships involved in walking, sitting and running, as the device only provides the basics and the specialist must decide personally on the measures to be taken.

This appliance must not be disposed of with household waste. Every consumer is obliged to take all electrical or electronic devices, regardless of whether they contain harmful substances or not, to a collection point in their town or to a retailer so that they can be disposed of in an environmentally friendly manner. Please contact the manufacturer regarding disposal.

The device requires no maintenance or calibration. A metrological check is not required for commercial use.

  • Disconnect the appliance from the socket before cleaning it. Do not use any liquid cleaners or sprays. Use a damp cloth for cleaning.
  • The measuring surface of the device must be cleaned with a soft cloth moistened with disinfectant before or after each use.
  • Only use the appliance again when it is completely dry.
  • Do not expose the device to direct sunlight and protect it from dirt and moisture.

Please install the driver for the device before connecting the scanner to the PC via USB. Please always use the latest driver. You can find this in the download area on our support page: gpsupport.com

The power supply unit supplied is required to operate the scanner. Connect the power supply unit to the designated connection (2) on the front of the device.

The mains plug must remain accessible as it fulfils the mains disconnection function.

Do not place any objects on the mains cable. Also ensure that people do not step on the power cable or get caught in it.

WARNING

Only use the original power supply unit for this device. The use of an unauthorised power supply unit can damage the device or be dangerous for this device.

 

 

Change view

After selecting one of the six available views, the measurement is displayed in this view.

 

 

 

 

 

Bunion line and foot axis

After activating the view of below you can move the displayed bale line with the left mouse button. To adjust the foot axis, you can rotate the foot in the front or rear foot area by holding down the left mouse button.

Start measurements

Left-click on the [Start measurement] button to activate the scanner and start a new measurement.

Next, the separately installed driver for the scanner is started and automatically carries out the initialisation process.

As soon as the scanner is initialised, all buttons are active. If you want to work with the foot switch, the "Use foot pedal" checkbox should be ticked. Then select the side you want to start with (left/right or both) and start the scanning process by pressing the foot switch or CTRL. If you have selected "Both", always start the scanning process with the left foot.

If you are not using a foot control, activate the scanning process by clicking on "Left" or "Right".

After scanning, a preview image is displayed. If both feet or just one foot have been scanned, the measurements are saved by clicking Apply. If a measurement is already open, you will be notified and you can decide whether to create a new file or overwrite the old measurement. The measurement is then displayed in the workspace.

Insert notes

You can create your notes by left-clicking in the free text field. These are saved with the customer under the measurement.