The measurement is generally displayed and viewed from the heel at the bottom to the toes at the top. If this display is incorrect, it can be rotated via an ini entry.

\GPSystem\GpSystem_single_seat
DV_MultiSens_PSAABT.INI
I_degree = 180 //0, 90, 180, 270, 360

I_degree can now be changed in a clockwise direction (ascending to the right, descending to the left).

If there are several individual workstations (profiles) in the GPSystem folder, you can find the correct individual workstation by right-clicking on the desktop shortcut and selecting Properties in the Target section.