Why does an error message with error 49 appear?
Error description
An error appears in the milling programme with the message Error 49.
Cause of error
The emergency stop switch on the milling machine was actuated. The system was then reset in the wrong order.
Troubleshooting
- Press the emergency stop switch on the milling machine again.
- First reset the emergency stop switch on the tiller by turning it.
- Reset the milling programme.