Why does the milling machine move to the limit switch when approaching the rest position?

, , , , , ,

Error description

When the tiller reaches the rest position, it immediately moves to the limit switch.

Cause of error

An incorrect value has been entered when determining the zero point.

Troubleshooting

If you have determined the value for the zero point in the GP Manager, you must enter it with a minus sign. If you have changed the zero point and then this error occurs, you have probably forgotten the minus sign in front of the value. The milling machine triggers the limit switch. This is how you set the zero point correctly:

  1. Follow the instructions for determining the zero point
  2. Ensure that the remote programme is started on the milling machine and that there is a network connection between the milling computer and the computer on which the GP Manager is installed.
  3. Start the GP Manager
  4. Select "Analysis"->"GP milling machine
  5. Click on "Setting the zero point
  6. Enter the correct zero point in the dialogue that opens in the remote program.