1.Changing the output stages #

Before replacing the output stage, set the appropriate address for the output stages. The position of the switches for the two axes can be seen in the pictures below.

In case you are interested: The address is entered via the DIP switches in the binary system (switches 1-5 correspond to 2⁰ to 2⁴, in the example below this results in 1*2⁰ + 1*2⁴ = 17).

Abbildung DIP-Schalter

Figure 1: Assignment of the DIP switches

DIP switch position for the X-axis (address: 1):

DIP-Schaltung-X-Achse

Figure 2: DIP circuit for address 1

DIP switch position for the Y-axis (address: 2):

DIP-Schaltung-Y-Achse

Figure 3: DIP circuit for address 2

2.Transferring data between the output stages #

Data specific to the milling machine is stored on the output stage. This data may need to be transferred between the old and new output stage. If you are not sure whether this is necessary, please ask GeBioM mbH Support.

If you have set the DIP switches correctly and the data has been transferred, you can swap the output stages in the control cabinet 1 to 1.

3.Software settings #

After replacing the output stages, start the milling computer.

  • Select "Start" -> "Programmes" -> "AC Setup C269" (sometimes also ISEL Germany AG) -> "ACSETUP C269
  • At the top of the menu, select "File" -> "Open" -> mostly D:\Backup\cncWorkbench...\Control\CAN\DCF-Files to select the relevant DCF file.
  • Now go to Connection -> CAN settings
CAN-Einstellungen

Figure 4: Menu for the CAN settings

  • In the following menu, pay attention to the correct CAN node indicate!
    • 1 for X-axis
    • 2 for Y-axis
  • Select the DLL for CAN communication: C:\CNCWorkbench\Control\CAN\CAN_API.dll
  • Confirm with OK
CAN-Konfiguration

Figure 5: CAN configuration for X-axis (address: 1)

  • Select "Connection" -> "Online mode" (or click on the satellite dish).
Onlinemodus

Figure 6: Online mode

  • Select the PC to card option in the following dialogue.
PC-zur-Karte

Figure 7: PC to card option

  • If no message appears, you can exit online mode and close the programme. The question about saving is answered in the negative.
Suggest Edit